UK GENERATOR SPECIALISTS · WORLDWIDE EXPORT
Blackwell generators · Specified by FW Power

Bespoke Silent Diesel
& Rental Generators

The power you need.
The acoustic performance your site demands.

Specify a bespoke silent diesel generator for standby power, prime power or your rental fleet. FW Power brings the engine, alternator, acoustic enclosure, fuel system and controls into a package matched to your load, site and operating requirements.

UK projects and export supply · Single sets and fleet enquiries

Blue Blackwell rental specification acoustic diesel generator with protected controls and socket connections
Blackwell rental specification generator. Equipment and options are agreed for each build.
8.5 to 3,150 kVAPublished Blackwell range, from prime to standby ratings
Acoustic engineeringNoise, cooling and access considered together
Built to your briefSite-specific and rental fleet package options
A complete engineering brief

A silent generator should fit
the job, not just the space.

A bespoke acoustic diesel generator is a coordinated power package. Its engine and alternator must support the electrical demand, while the enclosure manages noise, weather protection, airflow and maintenance access.

FW Power can develop Blackwell generator proposals around prime or standby duty, space restrictions, fuel autonomy, noise-sensitive surroundings and the way your team connects and operates the equipment. We can compare suitable package options and define the scope for supply, delivery, installation and commissioning.

Blackwell Generators is owned and distributed by FW Power Generators Limited. This gives you a direct conversation with the power team about the machine and the practical work around it, including servicing, testing and ongoing support.

For projects specifying UK manufacture, tell us at the start. UK-assembled options are available; build origin varies across the range and is confirmed in your quotation.

01

Electrical performance

Running load, starting demand, power factor, duty and the behaviour of sensitive equipment.

02

Mechanical integration

Canopy, ventilation, exhaust, fuel storage, footprint and safe service access.

03

Operational control

Local or remote operation, transfer arrangements, protection and fleet requirements.

Bespoke diesel generator assembly in a workshop, with an acoustic enclosure and engine assemblies.
Bespoke generator assembly brings the engine, alternator and acoustic enclosure together.
Generator sizes and component selection

From compact site power
to large industrial packages.

Blackwell's published catalogue extends from 8.5 kVA prime to 3,150 kVA standby. These are the range endpoints on different duty ratings, not interchangeable outputs. We select the actual model and acoustic configuration for your application.

Compact single-phase through to large three-phase packages.Commercial and industrial backup power options.Engine choices for site-specific and larger installations.A broad range extending into multi-megawatt applications.Mid-range and larger industrial generating sets.
Published Blackwell engine ranges. Individual model ratings and options must be checked.
Engine rangePublished capacitySelection guidance
Perkins Premium8.5–2,500 kVA prime
Perkins EnergyMax9.8–2,500 kVA standby
Cummins DynoMax27.5–2,250 kVA standby
Baudouin EcoMax19.3–3,150 kVA standby
Doosan PowerMax220–1,000 kVA standby

Source: Blackwell's published generator catalogue, checked October 2026. Acoustic and rental configurations are subject to model-specific feasibility. The table does not represent ready-to-dispatch stock.

Grey acoustic diesel generator canopy with open service doors and access to its controls.
Acoustic canopy design allows access to the engine, controls and service points.

The right kVA is only the start.

A 500 kVA enquiry needs more detail than a rating alone. We review the required kW, voltage, frequency, phase, largest motor and permitted voltage or frequency dip. Ambient temperature and altitude may also affect available output.

Ask about Perkins, Cummins, Baudouin and Doosan engines, with suitable alternator options including Stamford and Leroy-Somer where available for the selected build. Alternator frame, excitation and motor-starting performance are confirmed against the load.

For long-running temporary power, use the appropriate prime rating and operating limits. For emergency backup, specify the required standby duty. Read our prime and standby guide.

Where several sets offer a better operational solution, our team can also discuss synchronised generator packages.

Sound attenuation, explained

Quieter operation starts
with a measurable target.

“Silent” and “super silent” describe reduced-noise equipment. They do not mean soundless operation or a universal noise rating. We start with where the sound matters and how the generator will run.

Compare the same measurements.

Sound pressure, LpA, in dB(A) is measured at a stated position. Distance, load, surfaces and background noise affect the result. A reading at 7 metres cannot be compared directly with one at 1 metre.

Sound power, LWA, characterises the source's sound emission. It is a different quantity, even when also expressed in A-weighted decibels. Check which figure a datasheet gives.

For a site limit, agree the receptor or boundary position, operating condition and measurement method. A nearby wall, a reflective courtyard or several running generators can change the assessment.

Understand generator noise and dB(A)
01

Canopy & lining

Panel construction, acoustic absorption and sealed access points help control noise breaking out of the enclosure.

02

Air-path attenuation

Inlet and discharge treatment can reduce noise while preserving the cooling airflow the machine needs.

03

Exhaust treatment

Silencer selection and exhaust routing must respect the engine's permitted backpressure.

04

Vibration & location

Appropriate isolation, flexible connections and placement help address structure-borne noise and site impact.

Cooling must remain effective. Extra acoustic treatment can increase airflow resistance and enclosure size. We consider radiator capability, heat rejection, access and exhaust restrictions alongside the noise target. Achievable performance and verification are agreed for the proposed installation.

For hire fleets and demanding applications

Rental specification generators
built to order.

A rental-ready build should make repeated transport, connection, operation and servicing practical. Tell us how your fleet works so the specification supports your customers and engineers.

Connections that suit the job

Discuss single-phase and three-phase socket panels, protected outlets, hardwired termination or suitable high-current connectors. Outlet ratings, phase balance, cable entry and access need to match the generator and distribution design.

Fuel systems for the shift

Consider an integral tank, extended running arrangements, bunded containment and provision for an external tank. Fuel supply and return arrangements, valves, filtration and autonomy are specified for the selected engine and expected load.

Handling & protection

Ask about strengthened enclosure and base arrangements, protected controls, lifting provisions, forklift access and corrosion protection. Confirm lifting configuration, operating weight and transport requirements rather than assuming every feature suits every model.

Controls & fleet visibility

Local operation, automatic start, event records and remote monitoring can be assessed. Where appropriate, discuss synchronising, load-demand control and integration with your fleet's operating procedures.

Electrical protection

Breaker selection, fault protection, neutral arrangements and earthing need a coordinated design. Earth-leakage or residual-current protection is selected for the intended system, loads and discrimination requirements.

Serviceability & presentation

Plan access to filters, drains, batteries and service points, with clear identification and documentation. Discuss fleet colours, branding, a repeatable build specification and the spare-parts information your technicians need.

Options are assessed and priced against the chosen model. Stage V engine requirements are a separate specification decision: a rental canopy alone does not establish emissions compliance. Our team can explain suitable choices for the intended market and use.

Temporary power, specified for the application

One rental fleet can serve
very different industries.

These are applications to discuss with our team. They illustrate why a common canopy is not enough: each job has its own load profile, operating environment and connection requirements.

Plant hire & construction

Site compounds, welfare facilities, lighting and tools. Prioritise rugged handling, practical outlets, fuel autonomy and motor starts.

Civil engineering & rail works

Temporary compounds, pumps and planned infrastructure works. Review restricted access, shift length, noise limits and site approvals.

Film, television & broadcast

Location lighting, production facilities and technical equipment. Acoustic targets and load changes need early assessment.

Events, festivals & sport

Staging, catering, temporary buildings and lighting. Consider phase balance, distribution, overnight noise and reserve capacity.

Manufacturing & processing

Planned shutdowns and temporary production power. Check starting currents, load steps and operating hours.

Water, drainage & utilities

Pumping, treatment support and outage works. Starting duty, remote alarms and refuelling access can determine the package.

Agriculture & food production

Irrigation, ventilation, processing and seasonal loads. Review motors, environmental exposure and critical temperature control.

Ports, logistics & cold storage

Yard operations and temporary warehouse or refrigeration support. Evaluate continuous demand, corrosion exposure and load sequencing.

Telecoms & remote infrastructure

Temporary sites and maintenance cover. Fuel autonomy, monitoring, security and low-load operation warrant attention.

Retail, hospitality & estates

Refurbishment, business continuity and temporary facilities. Site boundaries, public access and unobtrusive operation matter.

Healthcare & data centres

Temporary resilience during planned works. Engineered transfer, protection and continuity arrangements require specialist coordination; a generator alone does not provide uninterrupted power.

Quarries & emergency response

Mobile operations, recovery work and remote support. Assess dust, access, weather, starting loads and dependable refuelling arrangements.

Explore generator applications by industry

Grey acoustic generator enclosure with ventilation grilles and open maintenance access doors.
Ventilation and maintenance access are considered alongside the acoustic enclosure design.
Generator assembly & component availability

Bespoke generator builds
and component availability.

A bespoke generator brings the engine, alternator, controls and acoustic enclosure into one coordinated build. For your order, we check the required components and production schedule against your power demand, noise target and delivery date.

Engine stock levels
Request current quantities by engine model.
Alternator stock levels
Matching frame, output and excitation confirmed.
Build allocation & lead time
Confirmed in your project quotation.

The photographs illustrate generator assembly and enclosure design, not current stock quantities. Component availability and build lead times are confirmed in your quotation.

Check components for your build
From requirement to handover

A clear specification.
A defined delivery scope.

  1. Understand the load

    Share the application, duty, load schedule, noise target, site details and required date.

  2. Compare the options

    Review suitable engines, alternators, enclosure design, fuel systems and control arrangements.

  3. Agree the build

    Confirm dimensions, scope, documentation, testing, price and lead time before proceeding.

  4. Plan the handover

    Coordinate delivery and any agreed installation, commissioning, operator familiarisation and service support.

Define the evidence you need.

Discuss load-bank testing, functional checks, control settings, documentation and any acoustic acceptance measurements as part of the order. A factory test and an installed-site test answer different questions. The agreed test schedule should state the load, conditions and acceptance criteria.

Generator testing & pre-delivery preparation

Bespoke diesel generator testing,
specified for your project.

A bespoke generator specification should cover how the finished package will be checked as well as how it will be built. For standby power, prime power and rental fleet applications, discuss the test programme with FW Power at the quotation stage.

Agree the factory test scope.

Specify the checks and records you need for your diesel generator. These may include generator load-bank testing, controller settings, alarm and shutdown checks, and recorded operating readings. Agree the load stages, duration and acceptance criteria for the selected engine, alternator and control package.

If your project requires a witnessed factory acceptance test (FAT), ask us to include attendance arrangements and the required test documentation in the quotation. Any acoustic performance measurements should also have an agreed method and operating conditions.

Connect testing with site handover.

Factory testing and generator installation and commissioning cover different parts of the project. Site commissioning considers the installed fuel, exhaust, ventilation, electrical connections and control arrangements within the agreed scope.

Tell us about your automatic transfer switch, remote-start signals or synchronised generator system so the testing and handover plan can address the proposed installation. Ongoing generator servicing and maintenance can then be planned around the application and operating hours.

Include your required test records, witness requirements and delivery date when you request a bespoke generator quotation.

Discuss your build & testing
Useful answers

Bespoke silent
generator FAQs

Planning an acoustic generator or specifying the next addition to your rental fleet? These are useful starting points for your conversation with our team.

What testing should I specify for a bespoke diesel generator?

Agree the test scope before placing the order. Depending on the package, this can include load-bank testing, controller and alarm checks, recorded operating readings and a witnessed factory acceptance test. State the required load stages, duration, acceptance criteria and documentation in your enquiry. Acoustic measurements and installed-site commissioning are separate requirements to agree for your project.

What is a bespoke silent diesel generator?

It is a diesel generating set specified around the site and load, with an acoustic enclosure and noise-control measures selected for the application. Silent is an industry description for reduced noise, not zero noise. The quotation should define the output, duty, sound target, measurement conditions and supplied equipment.

What generator sizes can FW Power supply through Blackwell?

The published Blackwell catalogue spans 8.5 kVA prime to 3,150 kVA standby across its ranges. Prime and standby are different ratings. We confirm the suitable model, prime kW and kVA, enclosure, engine, alternator and rental options against your project rather than assuming every configuration is available at every output.

Can you build rental specification generators to order?

Yes. FW Power can discuss Blackwell packages for hire fleets and end users, with options for acoustic treatment, fuel arrangements, socket panels, controls and handling. We agree a model-specific build specification and confirm feasibility, availability and lead time in the quotation. This page concerns equipment supply, rather than a short-term hire booking.

Can I specify 65 dB(A) at 7 metres or another sound target?

Tell us the target, operating load, measurement positions and site conditions. A number such as 65 dB(A) at 7 metres is a design brief to assess, not a standard performance promise for every generator. We confirm the achievable proposal and the evidence or acceptance test required before an order is agreed.

Are engine and alternator stock levels shown live?

No. The photographs illustrate generator assembly and enclosure design, not current stock quantities. Ask our team for current quantities and allocations by engine model and alternator frame. Component availability and build lead times are confirmed in your quotation. A stocked component does not mean a complete acoustic generator is available immediately.

Are all bespoke Blackwell generators manufactured in the UK?

Blackwell is a British generator brand owned and distributed by FW Power. UK-assembled options are available, while build origin and component sourcing vary by range. If UK manufacture is part of your purchasing specification, state this at enquiry so the quotation confirms the proposed package and origin.

Does rental specification automatically mean Stage V?

No. Rental specification describes the package and its practical features. Engine emissions certification is a separate selection requirement. Tell us where and how the generator will be used so we can assess an appropriate emissions specification, including Stage V options where required.

Can a bespoke generator work with an ATS or other generators?

Automatic transfer and synchronised generator operation can be considered as part of the package. The controller, governor, alternator, switchgear and protection must be compatible with the intended arrangement. An ordinary ATS changes between supplies; it does not by itself provide generator paralleling.

Talk to the power specialists

Tell us what
your generator needs to do.

Send us your brief and we will discuss suitable Blackwell options, current component availability and the next steps towards a quotation.

  • Required kVA/kW and prime or standby duty
  • Voltage, phase, frequency and the largest starting load
  • Application, quantity, location and required date
  • Noise target, distance and operating hours
  • Tank autonomy, outlets and control requirements
  • Available space, access and delivery scope

Not all details known yet? Tell us what you have and our team will help identify the remaining information.

Your bespoke generator enquiry

Share the essentials and our team will help develop your specification.

Your email app will open with the FW Power team as recipients. Press Send there to submit your enquiry.

Let’s put your power in place.

Tell us what you need to power. We’ll help you find the right solution.

Talk to our team